Product Short Description: Autotreat is a boiler water conditioner designed for optimum protection of boiler systems when used in conjunction with Oxygen Scavenger Plus. This well known phosphate treatment with new polymer technology. which helps to keep precipitates soft and no adherent for easy removal by blow down.
Product Description:

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical:

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical – Complete Solution for Boiler Protection

Boilers are critical equipment in marine and industrial operations, and maintaining proper water quality is essential for efficient performance and long service life. Poor boiler water treatment can lead to scale formation, corrosion, sludge buildup, and reduced heat transfer efficiency. AUTOTREAT Boiler Water Treatment Chemical is specially formulated to provide complete protection for boiler systems.

Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with Oxygen Scavenger Plus. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and no adherent for easy removal by blow down. The product should always be used in conjunction with an oxygen scavenger, preferably RXSOL Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.

Product Application:

Boiler Water Treatment Chemical Autotreat : Autotreat is a multifunctional, liquid boiler water treatment, formulated with alkaline compounds, scale inhibitor, dispersant, and volatile amines for the protection of the feed, boiler and condensate systems.
 

What is Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical?

 

Boiler Water Treatment AUTOTREAT is a multi-functional boiler water treatment chemical designed to control alkalinity, corrosion, scale formation, and sludge deposition in boiler systems. Its advanced formulation helps maintain clean boiler internals, ensuring safe and efficient operation.

It is widely used in:

  • Marine boilers

  • Industrial steam boilers

  • Heating systems

  • Auxiliary boilers

  • Closed water circulation systems

Why Boiler Water Treatment is Important?

 

Untreated boiler water can cause:

  • Scale formation that reduces heat transfer

  • Corrosion leading to metal damage and leaks

  • Sludge accumulation causing blockages

  • Fuel wastage due to poor efficiency

  • Boiler downtime and expensive repairs

Using a quality boiler treatment chemical like AUTOTREAT helps avoid these problems.

Product Dose:

The product should preferably be dosed continuously with a Rxsol Boiler Water Treatment Dosing Unit. Alternatively the product can be fed into the feed line by means of a by-pass pot feeder.

Dosage and control

Minimum dosage is 1.2 liters of Autotreat/ton of boiler capacity to reach a P-Alkalinity level of 100 ppm. For an untreated system it is recommended to initially bring the treatment up to a suitable level of 200 ppm p-Alkalinity. The dosage chart given below is for convenience to determine the amount of product required to elevate P-Alkalinity. Note that the table is based on reaching 200 ppm. P-Alkalinity.

 

Sampling and testing

A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Spectrapak Test Kit instructions and log the results. It is important that regular testing is carried out to ensure that treatment levels are correct.
 

Key Benefits of Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical

1. Prevents Scale Formation

Boiler Water Treatment AUTOTREAT controls hardness salts and prevents scale buildup inside boiler tubes.

2. Controls Corrosion

Protects boiler metal surfaces against oxygen and acidic corrosion.

3. Maintains Alkalinity

Helps maintain the proper pH and alkalinity level for efficient boiler operation.

4. Reduces Sludge Build-Up

Conditions suspended solids for easy removal during blowdown.

5. Improves Boiler Efficiency

Keeps heat transfer surfaces clean for better fuel economy.

6. Extends Boiler Life

Regular use helps prolong the lifespan of boiler systems.

Product Note:

Applications of Boiler Water Treatment AUTOTREAT

  • Marine boiler water treatment

  • Industrial boiler maintenance

  • Steam generation systems

  • Auxiliary boiler protection

  • Closed-loop heating systems

How to Use Boiler Water Treatment AUTOTREAT Boiler Chemical

  1. Test boiler water parameters.

  2. Dose Boiler Water Treatment AUTOTREAT directly into the boiler feed system.

  3. Maintain recommended alkalinity and pH levels.

  4. Perform regular blowdown to remove sludge.

  5. Monitor water quality for best results.

Dosage depends on boiler capacity and water conditions.

 

  • Liquid boiler water treatment chemical for simplified dosing and handling.
  • Suitable for all boilers, up to 30 Bar pressure.
  • Prevents scaling and corrosion, increasing system life and reliability.
  • Contains volatile amines to neutralize acids occurring in condensate system.
  • Dispersant action suspends sludge and sediment particles for efficient removal by blow down.
  • Suitable for dosing with Rxsol Boiler Water Treatment Dosing Unit.
  • Keeps boiler tube surfaces clean, promoting the best heat transfer conditions, saving energy.
  • Simple testing to determine treatment level.
Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates